Implanted Cardioverter-Defibrillator
Report:Implanted cardioverter-defibrillator (ICD) readout 1 Ventricular tachycardia 152 – 162/min 4 Burst overdrive pacing 190-245/min 4 Sinus rhythm 95/min 1 Comment:The patient had numerous runs of VT which failed to activate the ICD because the ra
Shifting Rabbit Ears in VT
Report: Ventricular tachycardia 152/min Possible old anterior infarction Comment: There is a monophasic R, possibly a qR, in V1, with northwest axis in the standard leads and QSs in V5-6. The patient in fact had an old anterior MI (Fig 106a below, in AF
Cardioverter-Defibrillator During Ventricular Tachycardia
Report:Ventricular tachycardia 133/min Burst of overdrive pacing 160/min Fusion beat Comment:This is the same patient as Case 4, five years later. The ICD does not always work, but the patient is alive, with numerous episodes of VT perhaps rendered les