Left Axis Deviation in WPW Conduction
Report:
Sinus arrhythmia 58 â 100/min
Left axis deviation â40o
Wolff-Parkinson-White conduction, type âBâ
Comment:
Either type âAâ or âBâ can produce inferior Q waves, usually QS complexes; âAâ, of course, can mimic posterior infarcts while âBâ may resemble anterior infarcts.
The PR interval may be normal in WPW conduction and indeed tends to get longer with age, but in most cases this is an illusion â either terminal P wave or the initial δ wave is isoelectric. In this example it is quite short, 0.10â. There is no PR segment: the QRS (δ wave) onset is at the end of the P wave.
The narrow-complex tachycardia in the country hospital was almost certainly an SVT.
Fig 21. Spastic 17 year old boy with no cardiac symptoms or history.
If you have any suggestions for or feedback on this report, please let us know.
Hi, can we chat about some terms and conditions?
The library and its records are licensed under the Creative Commons Attribution 4.0 International license.
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
By clicking agree below, you are agreeing to adhere to CC BY 4.0.