Hypercalcæmia

Report:

Sinus rhythm 89/min

Short QT interval c/c hypercalcæmia

Comment:

The actual QT measurement, just over 0.30”, yields a QTc of 0.38” – not a useful tool in a patient with calcium 4.64 mmol/L. Marriott suggest measuring the interval to the apex of the T wave, Q-aT interval, instead60. Here it can be easily seen in V2-3 that the T waves “hug” the QRS. It is even more obvious comparing the same patient’s ECG with normal calcium (Fig 83a below), at 90/min, practically the same rate.

83a.

84. Holter tape of an 84 year old man found dead few hours later

If you have any suggestions for or feedback on this report, please let us know.